Reviews

Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis

Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Published: 19 October 2026
28
Views
8
Downloads

Authors

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and a major cause of ischemic stroke. Because AF is frequently paroxysmal and asymptomatic, conventional short-term monitoring often fails to detect it. Wearable technologies have emerged as promising tools for AF screening, but their diagnostic performance requires comprehensive evaluation. We conducted a systematic review and diagnostic test accuracy meta-analysis following PRISMA-DTA guidelines. PubMed, Embase, and the Cochrane Library were searched from inception to 25 February 2026 for prospective and retrospective studies using electrocardiographic reference standards. Bivariate random-effects and Bayesian hierarchical models were used to pool diagnostic accuracy estimates. Fifty-one studies involving 33,374 participants from 15 countries were included. PPG-based smartwatches demonstrated the highest sensitivity (96.3%) with specificity of 93.6%. ECG-based smartwatches achieved sensitivity of 89.0% and specificity of 92.8% (DOR 103.9). Smartphone-based ECG devices showed the strongest overall diagnostic performance, with sensitivity of 94.5%, specificity of 95.8%, DOR of 396.4, LR+ of 22.6, and LR− of 0.057. Smartphone-based PPG applications achieved sensitivity of 92.0% and specificity of 91.9%. Apple Watch demonstrated sensitivity of 94.1% and specificity of 94.6%. Meta-regression revealed no statistically significant differences in diagnostic accuracy between device categories despite slightly higher point estimates for PPG-based smartwatches. No significant publication bias was detected (Deeks' test, p=0.18). Wearable devices demonstrate excellent diagnostic accuracy for AF detection, particularly smartphone-based ECG applications. These technologies support scalable AF screening and monitoring, although heterogeneity in study populations and diagnostic thresholds should be considered when applying these findings to routine clinical practice.

Downloads

Download data is not yet available.

Citations

1. Lippi G, Sanchis-Gomar F, Cervellin G. Global epidemiology of atrial fibrillation: an increasing epidemic and public health challenge. Int J Stroke 2021;16:217-21.
2. Wolf PA, Abbott RD, Kannel WB. Atrial fibrillation as an independent risk factor for stroke: the Framingham Study. Stroke 1991;22:983-8.
3. Hindricks G, Potpara T, Dagres N, et al. 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 2021;42:373-498.
4. Sanna T, Diener HC, Passman RS, et al. Cryptogenic stroke and underlying atrial fibrillation. N Engl J Med 2014;370:2478-86.
5. Himmelreich JCL, Karregat EPM, Lucassen WAM, et al. Diagnostic accuracy of a smartphone-operated, single-lead electrocardiography device for detection of rhythm and conduction abnormalities in primary care. Ann Fam Med 2019;17:403-11.
6. Bumgarner JM, Lambert CT, Hussein AA, et al. Smartwatch algorithm for automated detection of atrial fibrillation. J Am Coll Cardiol 2018;71:2381-8.
7. Svennberg E, Engdahl J, Al-Khalili F, et al. Mass screening for untreated atrial fibrillation: the STROKESTOP study. Circulation 2015;131:2176-84.
8. Tison GH, Sanchez JM, Ballinger B, et al. Passive detection of atrial fibrillation using a commercially available smartwatch. JAMA Cardiol 2018;3:409-16.
9. McManus DD, Lee J, Maitas O, et al. A novel application for the detection of an irregular pulse using an iPhone 4S in patients with atrial fibrillation. Heart Rhythm 2013;10:315-9.
10. Rozen G, Vaid J, Hosseini SM, et al. Diagnostic accuracy of a novel mobile phone application for the detection and monitoring of atrial fibrillation. Am J Cardiol 2018;121:1187-91.
11. Proesmans T, Mortelmans C, Van Haelst R, et al. Mobile phone-based use of the photoplethysmography technique to detect atrial fibrillation in primary care: diagnostic accuracy study of the FibriCheck app. JMIR Mhealth Uhealth 2019;7:e12284.
12. McInnes MDF, Moher D, Thombs BD, et al. Preferred reporting items for a systematic review and meta-analysis of diagnostic test accuracy studies: the PRISMA-DTA statement. JAMA 2018;319:388-96.
13. Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 2005;58:882-93.
14. Whiting PF, Rutjes AWS, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011;155:529-36.
15. Bonomi AG, Schipper F, Eerikäinen LM, et al. Atrial fibrillation detection using a novel cardiac ambulatory monitor based on photo-plethysmography at the wrist. J Am Heart Assoc 2018;7:e009351.
16. Chan NY, Choy CC, Chan CK, et al. Effectiveness of a nongovernmental organization-led large-scale community atrial fibrillation screening program using the smartphone electrocardiogram: an observational cohort study. Heart Rhythm 2018;15:1306-11.
17. Haberman ZC, Jahn RT, Bose R, et al. Wireless smartphone ECG enables large-scale screening in diverse populations. J Cardiovasc Electrophysiol 2015;26:520-6.
18. Prasitlumkum N, Cheungpasitporn W, Chokesuwattanaskul A, et al. Diagnostic accuracy of smart gadgets/wearable devices in detecting atrial fibrillation: a systematic review and meta-analysis. Arch Cardiovasc Dis 2021;114:4-16.
19. Luo DY, Zhang ZW, Sibomana O, et al. Comparison of diagnostic accuracy of ECG-based versus photoplethysmography-based smartwatches for atrial fibrillation detection: a systematic review and meta-analysis. Ann Med Surg (Lond) 2025.
20. [Authors to be added]. Accuracy of smartwatches in the detection of atrial fibrillation: a systematic review and diagnostic meta-analysis. JACC Adv 2025. doi:10.1016/j.jacadv.2025.102133.
21. Tarakji KG, Wazni OM, Callahan T, et al. Using a smartphone-based self-recording ECG system for detecting atrial fibrillation. J Am Coll Cardiol 2015;65:1486-7.
22. Guo Y, Wang H, Zhang H, et al. Mobile photoplethysmographic technology to detect atrial fibrillation. J Am Coll Cardiol 2019;74:2365-75.
23. Selder JL, Postema PG, Breur L, et al. A mobile health strategy for atrial fibrillation screening in the general population. Neth Heart J 2019;27:541-7.
24. Yan BP, Lai WH, Chan CK, et al. High-throughput, contactless and highly accurate detection of atrial fibrillation using a smartphone camera. Clin Cardiol 2018;41:1510-4.
25. Yan BP, Lai WHS, Chan CKY, et al. Contactless screening of atrial fibrillation by a smartphone-based facial video-based photoplethysmography: a pilot study. J Am Coll Cardiol 2018;71:A455.
26. Poh MZ, McDuff DJ, Picard RW. Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Opt Express 2010;18:10762-74.
27. Wasserlauf J, You C, Patel R, et al. Smartwatch performance for the detection and quantification of atrial fibrillation. Circ Arrhythm Electrophysiol 2019;12:e006834.
28. Gill S, et al. Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis. Heart 2022.
29. Bashar SK, Han D, Hajeb-Moghadam H, et al. Atrial fibrillation detection from wrist photoplethysmography signals using smartwatches. Sci Rep 2019;9:15054.
30. Han D, Bashar SK, Lázaro J, et al. A combined pulse rate variability and deep learning method for atrial fibrillation detection using a smartwatch. IEEE J Biomed Health Inform 2020;25:1567-75.
31. Ding EY, Bashar SK, Han D, et al. Accuracy of a smartwatch-based atrial fibrillation detection algorithm in a large hospital-based cohort. mHealth 2019;5:27.
32. Fiorina L, Labbé P, Sideris G, et al. Atrial fibrillation detection after cryptogenic stroke: long-term monitoring using a smartwatch. J Clin Med 2024;13:1125.
33. Steinhubl SR, Waalen J, Edwards AM, et al. Effect of a home-based wearable continuous ECG monitoring patch on detection of undiagnosed atrial fibrillation: the mSToPS randomized clinical trial. JAMA 2018;320:146-55.
34. Dörr M, Nohturfft V, Brasier N, et al. The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation. JACC Clin Electrophysiol 2019;5:199-208.
35. Nonoguchi M, Katano S, Hashimoto A, et al. Feasibility of a smartwatch for detecting atrial fibrillation in patients with suspected arrhythmia. CJC Open 2022;4:854-61.
36. Alnasser AW, Alghonaim M, Alonazi A, et al. Effectiveness of wearable devices for atrial fibrillation detection in the general population: a prospective observational study. J Pers Med 2023;13:782.
37. Chang HY, Yang PH, Wu YH, et al. Artificial intelligence-enabled electrocardiogram for the detection of atrial fibrillation: a systematic review and meta-analysis. J Clin Med 2022;11:5113.
38. Caillol T, Strik M, Ramirez FD, et al. Accuracy of Apple Watch for detection of atrial fibrillation. Circ Arrhythm Electrophysiol 2021;14:e008697.
39. Seshadri DR, Bittel B, Browsky D, et al. Accuracy of Apple Watch for detection of atrial fibrillation in patients with cardiovascular disease. npj Digit Med 2020;3:125.
40. Müller P, Heise S, Clauss S. Validation of a new smartwatch for the detection of atrial fibrillation in clinical practice. Sci Rep 2024;14:1023.
41. Ploux S, Strik M, Caillol T, et al. Performance of a smartwatch algorithm for the detection of atrial fibrillation in patients with sinus rhythm and premature contractions. Arch Cardiovasc Dis 2022;115:589-97.
42. Campo G, et al. Smartphone-based ECG for atrial fibrillation screening in high-risk patients. J Am Coll Cardiol 2022.
43. Abu-Alrub S, et al. Accuracy of Apple Watch for detection of atrial fibrillation in a clinical cohort. Circ Arrhythm Electrophysiol 2022.
44. Rajakariar K, Seshadri DR, Drumm S, et al. The role of smartphone ECG for the screening of atrial fibrillation in an underserved community. Med J Aust 2020;212:467-8.

How to Cite



1.
Abbas A, Hamid G, Kumar B, Hussain Qamari SM, Riaz H. Diagnostic accuracy of wearable technologies for atrial fibrillation detection: a systematic review and meta-analysis. Global Cardiol [Internet]. 2026 Oct. 19 [cited 2026 Oct. 22];4(3). Available from: https://www.globalcardiology.info/site/article/view/120